7. Appendix: Instrument Configurations and Specifications

7.1. WHOTS-19 300 kHz - Serial 7367

pc1


BEAM CONTINUITY TEST

When prompted to do so, vigorously rub the selected
beam's face.

If a beam does not PASS the test, send any character to
the ADCP to automatically select the next beam.


Rub Beam 1 = PASS
Rub Beam 2 = PASS
Rub Beam 3 = PASS
Rub Beam 4 = PASS

>rr
Recorder Directory:
Volume serial number for device #0 is 1633-17f2

  WHT19000 000               0 06-14-23  10:55:44p r  a [    0]

  Bytes used on device #0 = 0
Volume serial number for device #1 is 3357-0de5

  No files found.

  Bytes used on device #1 = 0
Total capacity   =  191969280 bytes
Total bytes used =          0 bytes in 1 files
Total bytes free =  191969280 bytes

>ck
[Parameters saved as USER defaults]
>deploy
Deployment Commands:
CF = 11101 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
CK ----------------------- Keep Parameters as USER Defaults
CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY)
CS ----------------------- Start Deployment

EA = +00000 -------------- Heading Alignment (1/100 deg)
EB = +00934 -------------- Heading Bias (1/100 deg)
ED = 01250 --------------- Transducer Depth (0 - 65535 dm)
ES = 35 ------------------ Salinity (0-40 pp thousand)
EX = 11111 --------------- Coord Transform (Xform: Type,Tilts,3 Bm,Map)
EZ = 1111101 ------------- Sensor Source (C,D,H,P,R,S,T)

RE ----------------------- Recorder ErAsE
RN ----------------------- Set Deployment Name

TE = 00:10:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100)
TF = 23/06/15,23:59:00 --- Time of First Ping (yr/mon/day,hour:min:sec)
TP = 00:04.00 ------------ Time per Ping (min:sec.sec/100)
TS = 23/06/14,23:04:18 --- Time Set (yr/mon/day,hour:min:sec)

WD = 111 100 000 --------- Data Out (Vel,Cor,Amp; PG,St,P0; P1,P2,P3)
WF = 0176 ---------------- Blank After Transmit (cm)
Press any key to continue
                       
WN = 030 ----------------- Number of depth cells (1-128)
WP = 00040 --------------- Pings per Ensemble (0-16384)
WS = 0400 ---------------- Depth Cell Size (cm)
WV = 175 ----------------- Mode 1 Ambiguity Vel (cm/s radial)

>cs

7.2. WHOTS-19 600 kHz - Serial 13917

ps0
  Instrument S/N:  13917
       Frequency:  614400 HZ
   Configuration:  4 BEAM, JANUS
     Match Layer:  10
      Beam Angle:  20 DEGREES
    Beam Pattern:  CONVEX
     Orientation:  UP
       Sensor(s):  HEADING  TILT 1  TILT 2  TEMPERATURE
Temp Sens Offset:  -0.03 degC

    CPU Firmware:  50.40 [0]
   Boot Code Ver:  Required:  1.16   Actual:  1.16
    DEMOD #1 Ver:  ad48, Type:  1f
    DEMOD #2 Ver:  ad48, Type:  1f
    PWRTIMG  Ver:  85d3, Type:   6

Board Serial-Number Data:
   A7  00 00 06 07 BD C0  09 PIO727-3000-00G
   D3  00 00 06 07 CC 88  09 CPU727-2000-00M
   8A  00 00 05 88 E4 75  09 REC727-1000-03E
   69  00 00 06 07 C9 BF  09 DSP727-2001-03H

ps3
Beam Width: 3.7 degrees

Beam  Elevation  Azimuth
 1     -70.00     270.00
 2     -70.00      90.00
 3     -70.00       0.01
 4     -70.00     180.00

Beam Directional Matrix (Down):
  0.3420  0.0000  0.9397  0.2419
 -0.3420  0.0000  0.9397  0.2419
  0.0000 -0.3420  0.9397 -0.2419
  0.0000  0.3420  0.9397 -0.2419

Instrument Transformation Matrix (Down)  Q14:
  1.4619  -1.4619   0.0000   0.0000       23952  -23952       0       0
  0.0000   0.0000  -1.4619   1.4619           0       0  -23952   23952
  0.2661   0.2661   0.2661   0.2661        4359    4359    4359    4359
  1.0337   1.0337  -1.0337  -1.0337       16936   16936  -16936  -16936
Beam Angle Corrections Are Loaded.

pa
PREDEPLOYMENT TESTS
CPU TESTS:
  RTC......................................PASS
  RAM......................................PASS
  ROM......................................PASS
RECORDER TESTS:
  PC Card #0...............................DETECTED
    Card Detect............................PASS
    Communication..........................PASS
    DOS Structure..........................PASS
    Sector Test (short)....................PASS
  PC Card #1...............................NOT DETECTED
DSP TESTS:
  Timing RAM...............................PASS
  Demod  RAM...............................PASS
  Demod  REG...............................PASS
  FIFOs....................................PASS
SYSTEM TESTS:
  XILINX Interrupts... IRQ3 IRQ3 IRQ3......PASS
  Wide Bandwidth...........................PASS
  Narrow Bandwidth.........................PASS
  RSSI Filter..............................PASS
  Transmit.................................PASS
SENSOR TESTS:
  H/W Operation.........................***FAIL***

pc1
BEAM CONTINUITY TEST
(Rub Beam 1-4 = PASS)

ac
ACTIVE FLUXGATE CALIBRATION MATRICES in NVRAM
Calibration date and time: 5/22/1923 23:59:09
S:
 Bx  4.6233e+01  4.5450e+01  2.9114e+02  2.8383e+02
 By  1.4861e+02  5.1542e+03  5.0860e+03  5.6730e+01
 Bz  2.1848e+01  2.0786e+01  3.4930e+01  2.7030e+02
Err  4.7694e+01  4.4911e+01  5.6584e+01  3.3404e+03
(Coils, tilt matrices, etc. omitted for brevity)

rf
RF = 31647714,223916032  --- Rec space used/free (bytes)
rs
RS = 031,213             --- Rec space used/free (MB)

rb
RECORDER TESTS: ...PASS
(running erase)
rs
RS = 000,244

rnwho19
cf11101

cs

7.3. WHOTS-19 MicroCAT - Headers

# Metadata for Sensor Serial Number: 6410
* <?xml version="1.0"?>
* <!--DeviceManager-->
* <SBEDataUploadFile>
* <ApplicationData>
* <DeviceInterfaceAppData>
* <SoftwareVersion>1.8.2</SoftwareVersion>
* <BuildDate>25-Jul-2018 07:49:42 UTC</BuildDate>
* </DeviceInterfaceAppData>
* </ApplicationData>
* <InstrumentState>
* <StatusData DeviceType='SBE56' SerialNumber='05606410'>
*    <DateTime>2024-06-08T06:39:40</DateTime>
*    <DelayedStart>2023-06-06T01:00:00</DelayedStart>
*    <EventSummary numEvents='0'/>
*    <Power>
*       <MainSupplyVoltage>3.64</MainSupplyVoltage>
*       </Power>
*    <ADCRatio>
*       <Ratio>7056416</Ratio>
*       </ADCRatio>
*    <Battery>
*       <Installed>2023-05-01T19:38:22</Installed>
*       <Samples>530257</Samples>
*       </Battery>
*    <MemorySummary>
*       <Samples>530257</Samples>
*       <Bytes>2207744</Bytes>
*       <BytesFree>64376832</BytesFree>
*       </MemorySummary>
*    </StatusData>
*
* <HardwareData DeviceType='SBE56' SerialNumber='05606410'>
*    <Manufacturer>Sea-Bird Electronics, Inc</Manufacturer>
*    <FirmwareVersion>SBE56 V0.98</FirmwareVersion>
*    <FirmwareDate>May  7 2019</FirmwareDate>
*    <PCBAssembly PCBID='101889' AssemblyNum='41688F'/>
*    <MfgDate>Feb 25 2011</MfgDate>
*    <PCBType>0</PCBType>
*    <InternalSensors>
*       <Sensor id='Water Temperature'>
*          <type>TEMP0</type>
*          <SerialNumber>05606410</SerialNumber>
*          </Sensor>
*       </InternalSensors>
*    </HardwareData>
*
* <ConfigurationData DeviceType='SBE56' SerialNumber='05606410'>
*    <Settings
*       samplePeriod='60' format='1' />
*    </ConfigurationData>
*
* <CalibrationCoefficients DeviceType='SBE56' SerialNumber='05606410'>
*    <Calibration format='TEMP0' id='Water Temperature'>
*       <CalDate>2023-02-18</CalDate>
*       <a0>-1.381770E-03</a0>
*       <a1>3.686239E-04</a1>
*       <a2>-7.899647E-06</a2>
*       <a3>2.292975E-07</a3>
*       <OFFSET>0.000000E+00</OFFSET>
*       </Calibration>
*    </CalibrationCoefficients>
*
* <EventSummary DeviceType='SBE56' SerialNumber='05606410'>
*    <EventList numEvents='0' maxStack='-2'>
*       </EventList>
*    </EventSummary>
*
* </InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
* ** WHOTS 19 STARBOARD 240 DEG - 80 CM BELOW DECK
* ]]>
* </UserHeaderInsert>
# nquan = 4
# nvalues = 530257
# units = specified
# name 0 = scan: Scan Count
# name 1 = timeJ: Julian Days
# name 2 = t090C: Temperature [ITS-90, deg C
# name 3 = flag:   0.000e+00
# span 0 =          1,     530257
# span 1 = 157.041667, 525.274988
# span 2 =    -0.0038,    34.3955
# span 3 =  0.000e+00,  0.000e+00
# interval = seconds: 60
# start_time = Jun 06 2023 01:00:00
# bad_flag =  -9.990e-29
# sensor 0 = RRatio temperature, 05606410
# datcnv_date = Jun 08 2024 18:21:57, SeatermUSB v 1.8.2
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE56\SBE56_6410.xml
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 6239
* <?xml version="1.0"?>
* <!--DeviceManager-->
* <SBEDataUploadFile>
* <ApplicationData>
* <DeviceInterfaceAppData>
* <SoftwareVersion>1.8.2</SoftwareVersion>
* <BuildDate>25-Jul-2018 07:49:42 UTC</BuildDate>
* </DeviceInterfaceAppData>
* </ApplicationData>
* <InstrumentState>
* <StatusData DeviceType='SBE56' SerialNumber='05606239'>
*    <DateTime>2024-06-08T06:44:19</DateTime>
*    <DelayedStart>2023-06-06T01:00:00</DelayedStart>
*    <EventSummary numEvents='0'/>
*    <Power>
*       <MainSupplyVoltage>3.62</MainSupplyVoltage>
*       </Power>
*    <ADCRatio>
*       <Ratio>7087738</Ratio>
*       </ADCRatio>
*    <Battery>
*       <Installed>2023-05-01T19:20:58</Installed>
*       <Samples>530263</Samples>
*       </Battery>
*    <MemorySummary>
*       <Samples>530263</Samples>
*       <Bytes>2207744</Bytes>
*       <BytesFree>64376832</BytesFree>
*       </MemorySummary>
*    </StatusData>
*
* <HardwareData DeviceType='SBE56' SerialNumber='05606239'>
*    <Manufacturer>Sea-Bird Electronics, Inc</Manufacturer>
*    <FirmwareVersion>SBE56 V0.98</FirmwareVersion>
*    <FirmwareDate>May  7 2019</FirmwareDate>
*    <PCBAssembly PCBID='101723' AssemblyNum='41688F'/>
*    <MfgDate>Feb 25 2011</MfgDate>
*    <PCBType>0</PCBType>
*    <InternalSensors>
*       <Sensor id='Water Temperature'>
*          <type>TEMP0</type>
*          <SerialNumber>05606239</SerialNumber>
*          </Sensor>
*       </InternalSensors>
*    </HardwareData>
*
* <ConfigurationData DeviceType='SBE56' SerialNumber='05606239'>
*    <Settings
*       samplePeriod='60' format='1' />
*    </ConfigurationData>
*
* <CalibrationCoefficients DeviceType='SBE56' SerialNumber='05606239'>
*    <Calibration format='TEMP0' id='Water Temperature'>
*       <CalDate>2023-02-18</CalDate>
*       <a0>-1.316669E-03</a0>
*       <a1>3.559913E-04</a1>
*       <a2>-7.039647E-06</a2>
*       <a3>2.108155E-07</a3>
*       <OFFSET>0.000000E+00</OFFSET>
*       </Calibration>
*    </CalibrationCoefficients>
*
* <EventSummary DeviceType='SBE56' SerialNumber='05606239'>
*    <EventList numEvents='0' maxStack='-2'>
*       </EventList>
*    </EventSummary>
*
* </InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
* ** WHOTS 19 FORWARD 180 DEG - 80 CM BELOW DECK
* ]]>
* </UserHeaderInsert>
# nquan = 4
# nvalues = 530263
# units = specified
# name 0 = scan: Scan Count
# name 1 = timeJ: Julian Days
# name 2 = t090C: Temperature [ITS-90, deg C
# name 3 = flag:   0.000e+00
# span 0 =          1,     530263
# span 1 = 157.041667, 525.279155
# span 2 =    -0.0009,    34.4112
# span 3 =  0.000e+00,  0.000e+00
# interval = seconds: 60
# start_time = Jun 06 2023 01:00:00
# bad_flag =  -9.990e-29
# sensor 0 = RRatio temperature, 05606239
# datcnv_date = Jun 08 2024 18:21:28, SeatermUSB v 1.8.2
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE56\SBE56_6239.xml
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 6412
* <?xml version="1.0"?>
* <!--DeviceManager-->
* <SBEDataUploadFile>
* <ApplicationData>
* <DeviceInterfaceAppData>
* <SoftwareVersion>1.8.2</SoftwareVersion>
* <BuildDate>25-Jul-2018 07:49:42 UTC</BuildDate>
* </DeviceInterfaceAppData>
* </ApplicationData>
* <InstrumentState>
* <StatusData DeviceType='SBE56' SerialNumber='05606412'>
*    <DateTime>2024-06-08T06:34:33</DateTime>
*    <DelayedStart>2023-06-06T01:00:00</DelayedStart>
*    <EventSummary numEvents='0'/>
*    <Power>
*       <MainSupplyVoltage>3.64</MainSupplyVoltage>
*       </Power>
*    <ADCRatio>
*       <Ratio>6927505</Ratio>
*       </ADCRatio>
*    <Battery>
*       <Installed>2023-05-01T19:37:26</Installed>
*       <Samples>530252</Samples>
*       </Battery>
*    <MemorySummary>
*       <Samples>530252</Samples>
*       <Bytes>2207232</Bytes>
*       <BytesFree>64377344</BytesFree>
*       </MemorySummary>
*    </StatusData>
*
* <HardwareData DeviceType='SBE56' SerialNumber='05606412'>
*    <Manufacturer>Sea-Bird Electronics, Inc</Manufacturer>
*    <FirmwareVersion>SBE56 V0.98</FirmwareVersion>
*    <FirmwareDate>May  7 2019</FirmwareDate>
*    <PCBAssembly PCBID='101848' AssemblyNum='41688F'/>
*    <MfgDate>Feb 25 2011</MfgDate>
*    <PCBType>0</PCBType>
*    <InternalSensors>
*       <Sensor id='Water Temperature'>
*          <type>TEMP0</type>
*          <SerialNumber>05606412</SerialNumber>
*          </Sensor>
*       </InternalSensors>
*    </HardwareData>
*
* <ConfigurationData DeviceType='SBE56' SerialNumber='05606412'>
*    <Settings
*       samplePeriod='60' format='1' />
*    </ConfigurationData>
*
* <CalibrationCoefficients DeviceType='SBE56' SerialNumber='05606412'>
*    <Calibration format='TEMP0' id='Water Temperature'>
*       <CalDate>2023-02-18</CalDate>
*       <a0>-1.289726E-03</a0>
*       <a1>3.514971E-04</a1>
*       <a2>-6.802816E-06</a2>
*       <a3>2.061836E-07</a3>
*       <OFFSET>0.000000E+00</OFFSET>
*       </Calibration>
*    </CalibrationCoefficients>
*
* <EventSummary DeviceType='SBE56' SerialNumber='05606412'>
*    <EventList numEvents='0' maxStack='-2'>
*       </EventList>
*    </EventSummary>
*
* </InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
* ** WHOTS 19 BOW 180 DEG - 100 CM BELOW DECK
* ]]>
* </UserHeaderInsert>
# nquan = 4
# nvalues = 530252
# units = specified
# name 0 = scan: Scan Count
# name 1 = timeJ: Julian Days
# name 2 = t090C: Temperature [ITS-90, deg C
# name 3 = flag:   0.000e+00
# span 0 =          1,     530252
# span 1 = 157.041667, 525.271516
# span 2 =    -0.0031,    35.3966
# span 3 =  0.000e+00,  0.000e+00
# interval = seconds: 60
# start_time = Jun 06 2023 01:00:00
# bad_flag =  -9.990e-29
# sensor 0 = RRatio temperature, 05606412
# datcnv_date = Jun 08 2024 18:22:09, SeatermUSB v 1.8.2
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE56\SBE56_6412.xml
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 6983
* <?xml version="1.0"?>
* <!--DeviceManager-->
* <SBEDataUploadFile>
* <ApplicationData>
* <DeviceInterfaceAppData>
* <SoftwareVersion>1.8.2</SoftwareVersion>
* <BuildDate>25-Jul-2018 07:49:42 UTC</BuildDate>
* </DeviceInterfaceAppData>
* </ApplicationData>
* <InstrumentState>
* <StatusData DeviceType='SBE56' SerialNumber='05606983'>
*    <DateTime>2024-06-08T06:24:52</DateTime>
*    <DelayedStart>2000-01-01T00:00:00</DelayedStart>
*    <EventSummary numEvents='0'/>
*    <Power>
*       <MainSupplyVoltage>3.63</MainSupplyVoltage>
*       </Power>
*    <ADCRatio>
*       <Ratio>6837154</Ratio>
*       </ADCRatio>
*    <Battery>
*       <Installed>2000-01-01T00:00:00</Installed>
*       <Samples>530243</Samples>
*       </Battery>
*    <MemorySummary>
*       <Samples>530243</Samples>
*       <Bytes>2207232</Bytes>
*       <BytesFree>64377344</BytesFree>
*       </MemorySummary>
*    </StatusData>
*
* <HardwareData DeviceType='SBE56' SerialNumber='05606983'>
*    <Manufacturer>Sea-Bird Electronics, Inc</Manufacturer>
*    <FirmwareVersion>SBE56 V0.96</FirmwareVersion>
*    <FirmwareDate>Feb 25 2011</FirmwareDate>
*    <PCBAssembly PCBID='108806' AssemblyNum='41688F'/>
*    <MfgDate>Feb 25 2011</MfgDate>
*    <PCBType>0</PCBType>
*    <InternalSensors>
*       <Sensor id='Water Temperature'>
*          <type>TEMP0</type>
*          <SerialNumber>05606983</SerialNumber>
*          </Sensor>
*       </InternalSensors>
*    </HardwareData>
*
* <ConfigurationData DeviceType='SBE56' SerialNumber='05606983'>
*    <Settings
*       samplePeriod='60' format='1' />
*    </ConfigurationData>
*
* <CalibrationCoefficients DeviceType='SBE56' SerialNumber='05606983'>
*    <Calibration format='TEMP0' id='Water Temperature'>
*       <CalDate>2023-02-18</CalDate>
*       <a0>-1.268043E-03</a0>
*       <a1>3.490084E-04</a1>
*       <a2>-6.664759E-06</a2>
*       <a3>2.024966E-07</a3>
*       <OFFSET>0.000000E+00</OFFSET>
*       </Calibration>
*    </CalibrationCoefficients>
*
* <EventSummary DeviceType='SBE56' SerialNumber='05606983'>
*    <EventList numEvents='0' maxStack='-2'>
*       </EventList>
*    </EventSummary>
*
* </InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
* ** WHOTS 19 BOW 180 DEG - 110 CM BELOW DECK
* ]]>
* </UserHeaderInsert>
# nquan = 4
# nvalues = 530243
# units = specified
# name 0 = scan: Scan Count
# name 1 = timeJ: Julian Days
# name 2 = t090C: Temperature [ITS-90, deg C
# name 3 = flag:   0.000e+00
# span 0 =          1,     530243
# span 1 = 157.041667, 525.265266
# span 2 =     0.0280,    34.3724
# span 3 =  0.000e+00,  0.000e+00
# interval = seconds: 60
# start_time = Jun 06 2023 01:00:00
# bad_flag =  -9.990e-29
# sensor 0 = RRatio temperature, 05606983
# datcnv_date = Jun 08 2024 18:22:20, SeatermUSB v 1.8.2
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE56\SBE56_6983.xml
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 7211
* <?xml version="1.0"?>
* <!--DeviceManager-->
* <SBEDataUploadFile>
* <ApplicationData>
* <DeviceInterfaceAppData>
* <SoftwareVersion>1.8.2</SoftwareVersion>
* <BuildDate>25-Jul-2018 07:49:42 UTC</BuildDate>
* </DeviceInterfaceAppData>
* </ApplicationData>
* <InstrumentState>
* <StatusData DeviceType='SBE56' SerialNumber='05607211'>
*    <DateTime>2024-06-08T06:48:31</DateTime>
*    <DelayedStart>2023-06-06T01:00:00</DelayedStart>
*    <EventSummary numEvents='0'/>
*    <Power>
*       <MainSupplyVoltage>3.67</MainSupplyVoltage>
*       </Power>
*    <ADCRatio>
*       <Ratio>7122864</Ratio>
*       </ADCRatio>
*    <Battery>
*       <Installed>2023-05-01T19:36:24</Installed>
*       <Samples>530267</Samples>
*       </Battery>
*    <MemorySummary>
*       <Samples>530267</Samples>
*       <Bytes>2207744</Bytes>
*       <BytesFree>64376832</BytesFree>
*       </MemorySummary>
*    </StatusData>
*
* <HardwareData DeviceType='SBE56' SerialNumber='05607211'>
*    <Manufacturer>Sea-Bird Electronics, Inc</Manufacturer>
*    <FirmwareVersion>SBE56 V0.98</FirmwareVersion>
*    <FirmwareDate>May  7 2019</FirmwareDate>
*    <PCBAssembly PCBID='112206' AssemblyNum='41688F'/>
*    <MfgDate>Feb 25 2011</MfgDate>
*    <PCBType>0</PCBType>
*    <InternalSensors>
*       <Sensor id='Water Temperature'>
*          <type>TEMP0</type>
*          <SerialNumber>05607211</SerialNumber>
*          </Sensor>
*       </InternalSensors>
*    </HardwareData>
*
* <ConfigurationData DeviceType='SBE56' SerialNumber='05607211'>
*    <Settings
*       samplePeriod='60' format='1' />
*    </ConfigurationData>
*
* <CalibrationCoefficients DeviceType='SBE56' SerialNumber='05607211'>
*    <Calibration format='TEMP0' id='Water Temperature'>
*       <CalDate>2023-02-18</CalDate>
*       <a0>-1.394984E-03</a0>
*       <a1>3.594659E-04</a1>
*       <a2>-6.970733E-06</a2>
*       <a3>2.124364E-07</a3>
*       <OFFSET>0.000000E+00</OFFSET>
*       </Calibration>
*    </CalibrationCoefficients>
*
* <EventSummary DeviceType='SBE56' SerialNumber='05607211'>
*    <EventList numEvents='0' maxStack='-2'>
*       </EventList>
*    </EventSummary>
*
* </InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
* ** WHOTS 19 PORT 120 DEG - 80 CM BELOW DECK
* ]]>
* </UserHeaderInsert>
# nquan = 4
# nvalues = 530267
# units = specified
# name 0 = scan: Scan Count
# name 1 = timeJ: Julian Days
# name 2 = t090C: Temperature [ITS-90, deg C
# name 3 = flag:   0.000e+00
# span 0 =          1,     530267
# span 1 = 157.041667, 525.281933
# span 2 =    -0.0033,    35.3820
# span 3 =  0.000e+00,  0.000e+00
# interval = seconds: 60
# start_time = Jun 06 2023 01:00:00
# bad_flag =  -9.990e-29
# sensor 0 = RRatio temperature, 05607211
# datcnv_date = Jun 08 2024 18:22:30, SeatermUSB v 1.8.2
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE56\SBE56_7211.xml
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 3382
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\danfi\Desktop\whots-19_mcats\w19_015m_3382.asc
* Software Version 1.59
* Temperature SN = 3382
* Conductivity SN = 3382
* System UpLoad Time = Jun 11 2024 00:14:29
** whots-19
** 15m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3382    06-11-2024  00:13:21
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 174243, free = 58773
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 15.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 19.73 deg C


* S>
* SBE37-SM V 2.6b  3382
* temperature:  14-apr-23
*     TA0 = -1.641162e-05
*     TA1 = 2.809134e-04
*     TA2 = -2.678836e-06
*     TA3 = 1.658588e-07
* conductivity:  14-apr-23
*     G = -1.015468e+00
*     H = 1.414975e-01
*     I = -1.302092e-04
*     J = 3.535856e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -6.932923e-06
* rtc:  14-apr-23
*     RTCA0 = 9.999800e-01
*     RTCA1 = 1.786062e-06
*     RTCA2 = -3.301592e-08


* S>
*END*

# Metadata for Sensor Serial Number: 6892
* Sea-Bird SBE37SM-RS232  Data File:
* FileName = C:\Users\Jefrey\Documents\WHOTS-19_recovery\w19_007m_6892.hex
* Software version SeatermV2 2.8.0.119
* Temperature SN = 6892
* Conductivity SN = 6892
* System UpLoad Time = Jun 08 2024 09:39:21
* sample interval = 75 seconds
* <ApplicationData>
* <Seaterm232>
* <SoftwareVersion>2.8.0.119</SoftwareVersion>
* <BuildDate>07-Nov-2018</BuildDate>
* </Seaterm232>
* </ApplicationData>
* <InstrumentState>
* <HardwareData DeviceType='SBE37SM-RS232' SerialNumber='03706892'>
*
*    <Manufacturer>Sea-Bird Electronics, Inc.</Manufacturer>
*
*    <FirmwareVersion>3.1</FirmwareVersion>
*
*    <FirmwareDate>Jan 20 2012 17:33:01</FirmwareDate>
*
*    <PCBAssembly>41647</PCBAssembly>
*
*    <PCBAssembly>41610B</PCBAssembly>
*
*    <PCBAssembly>41611D</PCBAssembly>
*
*    <MfgDate>16 Mar 2009</MfgDate>
*
*    <FirmwareLoader>SBE 37 FirmwareLoader V 1.0</FirmwareLoader>
*
*    <InternalSensors>
*
*       <Sensor id='Temperature'>
*
*          <type>temperature-1</type>
*
*          <SerialNumber>03706892</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Conductivity'>
*
*          <type>conductivity-1</type>
*
*          <SerialNumber>03706892</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Pressure'>
*
*          <type>strain-0</type>
*
*          <SerialNumber>2651324</SerialNumber>
*
*       </Sensor>
*
*    </InternalSensors>
*
* </HardwareData>
* <StatusData DeviceType='SBE37SM-RS232' SerialNumber='03706892'>
*
*    <DateTime>2024-06-08T04:46:41</DateTime>
*
*    <EventSummary numEvents='9'/>
*
*    <Power>
*
*       <vMain> 7.00</vMain>
*
*       <vLith> 3.15</vLith>
*
*    </Power>
*
*    <MemorySummary>
*
*       <Bytes>6224205</Bytes>
*
*       <Samples>414947</Samples>
*
*       <SamplesFree>144293</SamplesFree>
*
*       <SampleLength>15</SampleLength>
*
*    </MemorySummary>
*
*    <AutonomousSampling>no, stop command</AutonomousSampling>
*
* </StatusData>
* <ConfigurationData DeviceType='SBE37SM-RS232' SerialNumber='03706892'>
*
*    <PressureInstalled>yes</PressureInstalled>
*
*    <PumpInstalled>no</PumpInstalled>
*
*    <SampleDataFormat>converted engineering</SampleDataFormat>
*
*    <OutputSalinity>yes</OutputSalinity>
*
*    <OutputSV>no</OutputSV>
*
*    <TxRealTime>no</TxRealTime>
*
*    <SampleInterval>75</SampleInterval>
*
*    <SyncMode>no</SyncMode>
*
* </ConfigurationData>
* <CalibrationCoefficients DeviceType='SBE37SM-RS232' SerialNumber='03706892'>
*
*    <Calibration format='TEMP1' id='Temperature'>
*
*       <SerialNum>03706892</SerialNum>
*
*       <CalDate>14-Apr-23</CalDate>
*
*       <A0>6.752063e-05</A0>
*
*       <A1>2.680171e-04</A1>
*
*       <A2>-1.983505e-06</A2>
*
*       <A3>1.393184e-07</A3>
*
*    </Calibration>
*
*    <Calibration format='WBCOND0' id='Conductivity'>
*
*       <SerialNum>03706892</SerialNum>
*
*       <CalDate>14-Apr-23</CalDate>
*
*       <G>-1.015170e+00</G>
*
*       <H>1.481606e-01</H>
*
*       <I>-8.220501e-05</I>
*
*       <J>2.843512e-05</J>
*
*       <PCOR>-9.570000e-08</PCOR>
*
*       <TCOR>3.250000e-06</TCOR>
*
*       <WBOTC>1.282297e-07</WBOTC>
*
*    </Calibration>
*
*    <Calibration format='STRAIN0' id='Pressure'>
*
*       <SerialNum>2651324</SerialNum>
*
*       <CalDate>12-Apr-23</CalDate>
*
*       <PA0>2.575698e-01</PA0>
*
*       <PA1>5.037208e-03</PA1>
*
*       <PA2>-9.188744e-12</PA2>
*
*       <PTCA0>5.248322e+05</PTCA0>
*
*       <PTCA1>4.401518e+00</PTCA1>
*
*       <PTCA2>-9.524952e-02</PTCA2>
*
*       <PTCB0>2.625875e+01</PTCB0>
*
*       <PTCB1>-6.500000e-04</PTCB1>
*
*       <PTCB2>0.000000e+00</PTCB2>
*
*       <PTEMPA0>-7.111706e+01</PTEMPA0>
*
*       <PTEMPA1>4.915885e-02</PTEMPA1>
*
*       <PTEMPA2>-2.264329e-07</PTEMPA2>
*
*       <POFFSET>0.000000e+00</POFFSET>
*
*       <PRANGE>1.450000e+03</PRANGE>
*
*    </Calibration>
*
* </CalibrationCoefficients>
* <EventCounters DeviceType='SBE37SM-RS232' SerialNumber='03706892'>
*
*    <EventSummary numEvents='9'/>
*
*    <Event type='PON reset' count='3'/>
*
*    <Event type='alarm long' count='6'/>
*
* </EventCounters></InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
** WHOTS18 whots-19
** 55m 7m
* ]]>
* </UserHeaderInsert>
# nquan = 5
# nvalues = 414947
# units = specified
# name 0 = cond0S/m: Conductivity [S/m]
# name 1 = tv290C: Temperature [ITS-90, deg C]
# name 2 = prdM: Pressure, Strain Gauge [db]
# name 3 = timeJV2: Time, Instrument [julian days]
# name 4 = flag:  0.000e+00
# span 0 =   0.000032,   5.553009
# span 1 =     0.4905,    31.7238
# span 2 =     -0.248,     17.286
# span 3 = 165.000000, 525.196725
# span 4 = 0.0000e+00, 0.0000e+00
# interval = seconds: 75
# start_time = Jun 14 2023 00:00:00 [Instrument's time stamp, first data scan]
# bad_flag = -9.990e-29
# <Sensors count="3" >
#   <sensor Channel="1" >
#     <!-- Count, Temperature -->
#     <TemperatureSensor SensorID="58" >
#       <SerialNumber>6892</SerialNumber>
#       <CalibrationDate>14-Apr-23</CalibrationDate>
#       <A0>6.75206300e-005</A0>
#       <A1>2.68017100e-004</A1>
#       <A2>-1.98350500e-006</A2>
#       <A3>1.39318400e-007</A3>
#       <Slope>1.00000000</Slope>
#       <Offset>0.0000</Offset>
#     </TemperatureSensor>
#   </sensor>
#   <sensor Channel="2" >
#     <!-- Frequency 0, Conductivity -->
#     <ConductivitySensor SensorID="3" >
#       <SerialNumber>6892</SerialNumber>
#       <CalibrationDate>14-Apr-23</CalibrationDate>
#       <UseG_J>1</UseG_J>
#       <!-- Cell const and series R are applicable only for wide range sensors. -->
#       <SeriesR>0.0000</SeriesR>
#       <CellConst>2000.0000</CellConst>
#       <ConductivityType>1</ConductivityType>
#       <Coefficients equation="0" >
#         <A>0.00000000e+000</A>
#         <B>0.00000000e+000</B>
#         <C>0.00000000e+000</C>
#         <D>0.00000000e+000</D>
#         <M>0.0</M>
#         <CPcor>-9.57000000e-008</CPcor>
#       </Coefficients>
#       <Coefficients equation="1" >
#         <G>-1.01517000e+000</G>
#         <H>1.48160600e-001</H>
#         <I>-8.22050100e-005</I>
#         <J>2.84351200e-005</J>
#         <CPcor>-9.57000000e-008</CPcor>
#         <CTcor>3.2500e-006</CTcor>
#         <!-- WBOTC not applicable unless ConductivityType = 1. -->
#         <WBOTC>1.28229700e-007</WBOTC>
#       </Coefficients>
#       <Slope>1.00000000</Slope>
#       <Offset>0.00000</Offset>
#     </ConductivitySensor>
#   </sensor>
#   <sensor Channel="3" >
#     <!-- Count, Pressure, Strain Gauge -->
#     <PressureSensor SensorID="46" >
#       <SerialNumber>2651324</SerialNumber>
#       <CalibrationDate>12-Apr-23</CalibrationDate>
#       <PA0>2.57569800e-001</PA0>
#       <PA1>5.03720800e-003</PA1>
#       <PA2>-9.18874400e-012</PA2>
#       <PTEMPA0>-7.11170600e+001</PTEMPA0>
#       <PTEMPA1>4.91588500e-002</PTEMPA1>
#       <PTEMPA2>-2.26432900e-007</PTEMPA2>
#       <PTCA0>5.24832200e+005</PTCA0>
#       <PTCA1>4.40151800e+000</PTCA1>
#       <PTCA2>-9.52495200e-002</PTCA2>
#       <PTCB0>2.62587500e+001</PTCB0>
#       <PTCB1>-6.50000000e-004</PTCB1>
#       <PTCB2>0.00000000e+000</PTCB2>
#       <Offset>0.000000</Offset>
#     </PressureSensor>
#   </sensor>
# </Sensors>
# datcnv_date = Jun 13 2024 14:38:03, 7.26.7.129 [datcnv_vars = 4]
# datcnv_in = C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_007m_6892.hex C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_007m_6892.xmlcon
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 4663
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\Jefrey\Documents\WHOTS-19_recovery\w19_025m_4663.asc
* Software Version 1.59
* Temperature SN = 4663
* Conductivity SN = 4663
* System UpLoad Time = Jun 08 2024 03:41:26
** whots-19
** 25m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 4663    06-08-2024  03:40:13
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 172873, free = 60143
* transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 25.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 23.08 deg C


* S>
* SBE37-SM V 2.6b  4663
* temperature:  14-apr-23
*     TA0 = -3.651114e-05
*     TA1 = 2.838335e-04
*     TA2 = -2.961921e-06
*     TA3 = 1.728443e-07
* conductivity:  14-apr-23
*     G = -1.003258e+00
*     H = 1.345263e-01
*     I = -1.429068e-04
*     J = 3.196058e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -1.627869e-05
* rtc:  14-apr-23
*     RTCA0 = 9.999873e-01
*     RTCA1 = 1.636624e-06
*     RTCA2 = -3.073115e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3633
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\Jefrey\Documents\WHOTS-19_recovery\w19_035m_3633.asc
* Software Version 1.59
* Temperature SN = 3633
* Conductivity SN = 3633
* System UpLoad Time = Jun 07 2024 19:34:28
** whots19
** 035m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3633    06-07-2024  19:32:50
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 172710, free = 60306
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 35.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 19.58 deg C


* S>
* SBE37-SM V 2.6b  3633
* temperature:  14-apr-23
*     TA0 = -2.768427e-05
*     TA1 = 2.835877e-04
*     TA2 = -2.872635e-06
*     TA3 = 1.707177e-07
* conductivity:  14-apr-23
*     G = -1.019303e+00
*     H = 1.249950e-01
*     I = -6.729279e-05
*     J = 2.582730e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -1.458610e-05
* rtc:  14-apr-23
*     RTCA0 = 9.999830e-01
*     RTCA1 = 1.612749e-06
*     RTCA2 = -3.153742e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3381
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\18082\Desktop\WHOTS-19_mcats\w19_040m_3381_redownload.asc
* Software Version 1.59
* Temperature SN = 3381
* Conductivity SN = 3381
* System UpLoad Time = Jun 14 2024 22:52:39
** whots-19
** 40m
* ds
* SBE37-SM V 2.6a  SERIAL NO. 3381    06-14-2024  22:51:54
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 172866, free = 60150
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 40.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 20.12 deg C


* S>
* SBE37-SM V 2.6a  3381
* temperature:  14-apr-23
*     TA0 = -3.247691e-05
*     TA1 = 2.858018e-04
*     TA2 = -2.966298e-06
*     TA3 = 1.760258e-07
* conductivity:  14-apr-23
*     G = -1.010994e+00
*     H = 1.361200e-01
*     I = -1.202721e-04
*     J = 3.127186e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -7.273084e-06
* rtc:  14-apr-23
*     RTCA0 = 9.999795e-01
*     RTCA1 = 1.763587e-06
*     RTCA2 = -3.197946e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3668
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\Jefrey\Documents\WHOTS-19_recovery\w19_045m_3668.asc
* Software Version 1.59
* Temperature SN = 3668
* Conductivity SN = 3668
* System UpLoad Time = Jun 08 2024 03:10:09
** whots-19
** 45m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3668    06-08-2024  03:08:40
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 171871, free = 18779
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 22.92 deg C


* S>
* SBE37-SM V 2.6b  3668
* temperature:  14-apr-23
*     TA0 = -1.672365e-04
*     TA1 = 3.004901e-04
*     TA2 = -3.860882e-06
*     TA3 = 1.903495e-07
* conductivity:  14-apr-23
*     G = -1.035126e+00
*     H = 1.343027e-01
*     I = -7.020420e-05
*     J = 2.705898e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -1.218318e-05
* pressure S/N 5579, range = 1450 psia:  18-apr-23
*     PA0 = -1.426169e-01
*     PA1 = 6.859640e-02
*     PA2 = -2.686288e-09
*     PTCA0 = -1.108384e+03
*     PTCA1 = -2.486515e-01
*     PTCA2 = 7.003375e-03
*     PTCSB0 = 2.492287e+01
*     PTCSB1 = 3.750000e-04
*     PTCSB2 = 0.000000e+00
*     POFFSET = 0.000000e+00
* rtc:  14-apr23
*     RTCA0 = 9.999746e-01
*     RTCA1 = 1.727574e-06
*     RTCA2 = -3.404602e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3619
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\danfi\Desktop\whots-19_mcats\w19_050m_3619.asc
* Software Version 1.59
* Temperature SN = 3619
* Conductivity SN = 3619
* System UpLoad Time = Jun 11 2024 00:20:21
** whots-19
** 50m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3619    06-11-2024  00:19:06
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 174245, free = 58771
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 50.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 20.00 deg C


* S>
* SBE37-SM V 2.6b  3619
* temperature:  18-apr-23
*     TA0 = -1.251457e-04
*     TA1 = 2.839028e-04
*     TA2 = -2.620611e-06
*     TA3 = 1.569759e-07
* conductivity:  18-apr-23
*     G = -9.946066e-01
*     H = 1.356605e-01
*     I = -6.729854e-05
*     J = 2.731227e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -8.184573e-06
* rtc:  18-apr-23
*     RTCA0 = 9.999782e-01
*     RTCA1 = 1.690207e-06
*     RTCA2 = -3.328952e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3620
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\18082\Desktop\WHOTS-19_mcats\w19_055m_3620.asc
* Software Version 1.59
* Temperature SN = 3620
* Conductivity SN = 3620
* System UpLoad Time = Jun 11 2024 00:02:11
** whots-19
** 55m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3620    06-11-2024  00:01:23
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 174240, free = 58776
* transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 55.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 19.91 deg C


* S>
* SBE37-SM V 2.6b  3620
* temperature:  14-apr-23
*     TA0 = -5.229356e-05
*     TA1 = 2.839673e-04
*     TA2 = -2.957658e-06
*     TA3 = 1.706467e-07
* conductivity:  14-apr-23
*     G = -1.011294e+00
*     H = 1.367751e-01
*     I = -1.074528e-04
*     J = 2.917739e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -1.068942e-05
* rtc:  14-apr-23
*     RTCA0 = 9.999726e-01
*     RTCA1 = 1.710818e-06
*     RTCA2 = -3.067796e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3621
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\18082\Desktop\WHOTS-19_mcats\w19_065m_3621.asc
* Software Version 1.59
* Temperature SN = 3621
* Conductivity SN = 3621
* System UpLoad Time = Jun 10 2024 23:57:22
** whots-19
** 65m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3621    10 Jun 2024  23:56:24
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 174238, free = 58778
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 65.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 20.08 deg C


* S>
* SBE37-SM V 2.6b  3621
* temperature:  13-apr-23
*     TA0 = -4.412578e-06
*     TA1 = 2.728183e-04
*     TA2 = -2.034944e-06
*     TA3 = 1.476782e-07
* conductivity:  13-apr-23
*     G = -1.011447e+00
*     H = 1.421872e-01
*     I = -8.956687e-05
*     J = 2.994932e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -1.146184e-05
* rtc:  13-apr-23
*     RTCA0 = 9.999853e-01
*     RTCA1 = 1.633466e-06
*     RTCA2 = -3.146521e-08


* S>
*END*

# Metadata for Sensor Serial Number: 9988
* Sea-Bird SBE37SM-RS232  Data File:
* FileName = C:\Documents and Settings\Administrator\Desktop\WHOTS-19_recovery\w19_075m_9988.hex
* Software version SeatermV2 1.1j
* Temperature SN = 9988
* Conductivity SN = 9988
* System UpLoad Time = Jun 07 2024 21:44:44
* sample interval = 180 seconds
* <ApplicationData>
* <Seaterm232>
* <SoftwareVersion>1.1j</SoftwareVersion>
* <BuildDate>14-May-2012</BuildDate>
* </Seaterm232>
* </ApplicationData>
* <InstrumentState>
* <HardwareData DeviceType='SBE37SM-RS232' SerialNumber='03709988'>
*    <Manufacturer>Sea-Bird Electronics, Inc.</Manufacturer>
*    <FirmwareVersion>3.1</FirmwareVersion>
*    <FirmwareDate>Jan 20 2012 17:33:01</FirmwareDate>
*    <PCBAssembly>41647</PCBAssembly>
*    <PCBAssembly>41624A</PCBAssembly>
*    <PCBAssembly>41611D</PCBAssembly>
*    <MfgDate>8 Aug 2012</MfgDate>
*    <FirmwareLoader>SBE 37 FirmwareLoader V 1.0</FirmwareLoader>
*    <InternalSensors>
*       <Sensor id='Temperature'>
*          <type>temperature-1</type>
*          <SerialNumber>03709988</SerialNumber>
*       </Sensor>
*       <Sensor id='Conductivity'>
*          <type>conductivity-1</type>
*          <SerialNumber>03709988</SerialNumber>
*       </Sensor>
*    </InternalSensors>
* </HardwareData>
* <StatusData DeviceType='SBE37SM-RS232' SerialNumber='03709988'>
*    <DateTime>2024-06-07T20:23:33</DateTime>
*    <EventSummary numEvents='1'/>
*    <Power>
*       <vMain> 7.03</vMain>
*       <vLith> 3.15</vLith>
*    </Power>
*    <MemorySummary>
*       <Bytes>1727250</Bytes>
*       <Samples>172725</Samples>
*       <SamplesFree>666135</SamplesFree>
*       <SampleLength>10</SampleLength>
*    </MemorySummary>
*    <AutonomousSampling>no, stop command</AutonomousSampling>
* </StatusData>
* <ConfigurationData DeviceType='SBE37SM-RS232' SerialNumber='03709988'>
*    <PressureInstalled>no</PressureInstalled>
*    <ReferencePressure>7.500000e+01</ReferencePressure>
*    <PumpInstalled>no</PumpInstalled>
*    <SampleDataFormat>converted engineering</SampleDataFormat>
*    <OutputSalinity>yes</OutputSalinity>
*    <OutputSV>no</OutputSV>
*    <TxRealTime>no</TxRealTime>
*    <SampleInterval>180</SampleInterval>
*    <SyncMode>no</SyncMode>
* </ConfigurationData>
* <CalibrationCoefficients DeviceType='SBE37SM-RS232' SerialNumber='03709988'>
*    <Calibration format='TEMP1' id='Temperature'>
*       <SerialNum>03709988</SerialNum>
*       <CalDate>14-Apr-23</CalDate>
*       <A0>-5.159456e-05</A0>
*       <A1>2.990909e-04</A1>
*       <A2>-4.019862e-06</A2>
*       <A3>1.901382e-07</A3>
*    </Calibration>
*    <Calibration format='WBCOND0' id='Conductivity'>
*       <SerialNum>03709988</SerialNum>
*       <CalDate>14-Apr-23</CalDate>
*       <G>-9.806384e-01</G>
*       <H>1.494975e-01</H>
*       <I>-2.419426e-04</I>
*       <J>4.167856e-05</J>
*       <PCOR>-9.570000e-08</PCOR>
*       <TCOR>3.250000e-06</TCOR>
*       <WBOTC>1.950041e-07</WBOTC>
*    </Calibration>
* </CalibrationCoefficients>
* <EventCounters DeviceType='SBE37SM-RS232' SerialNumber='03709988'>
*    <EventSummary numEvents='1'/>
*    <Event type='PON reset' count='1'/>
* </EventCounters></InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
** Cruise WHOTS-19
** depth 075m
* ]]>
* </UserHeaderInsert>
# nquan = 5
# nvalues = 172725
# units = specified
# name 0 = cond0S/m: Conductivity [S/m]
# name 1 = tv290C: Temperature [ITS-90, deg C]
# name 2 = prM: Pressure [db]
# name 3 = timeJV2: Time, Instrument [julian days]
# name 4 = flag:  0.000e+00
# span 0 =  -0.000029,   5.570318
# span 1 =     0.0666,    31.0193
# span 2 =     75.000,     75.000
# span 3 = 165.000000, 524.841667
# span 4 = 0.0000e+00, 0.0000e+00
# interval = seconds: 180
# start_time = Jun 14 2023 00:00:00 [Instrument's time stamp, first data scan]
# bad_flag = -9.990e-29
# <Sensors count="2" >
#   <sensor Channel="1" >
#     <!-- Count, Temperature -->
#     <TemperatureSensor SensorID="58" >
#       <SerialNumber>9988</SerialNumber>
#       <CalibrationDate>14-Apr-23</CalibrationDate>
#       <A0>-5.15945600e-005</A0>
#       <A1>2.99090900e-004</A1>
#       <A2>-4.01986200e-006</A2>
#       <A3>1.90138200e-007</A3>
#       <Slope>1.00000000</Slope>
#       <Offset>0.0000</Offset>
#     </TemperatureSensor>
#   </sensor>
#   <sensor Channel="2" >
#     <!-- Frequency 0, Conductivity -->
#     <ConductivitySensor SensorID="3" >
#       <SerialNumber>9988</SerialNumber>
#       <CalibrationDate>14-Apr-23</CalibrationDate>
#       <UseG_J>1</UseG_J>
#       <!-- Cell const and series R are applicable only for wide range sensors. -->
#       <SeriesR>0.0000</SeriesR>
#       <CellConst>2000.0000</CellConst>
#       <ConductivityType>1</ConductivityType>
#       <Coefficients equation="0" >
#         <A>0.00000000e+000</A>
#         <B>0.00000000e+000</B>
#         <C>0.00000000e+000</C>
#         <D>0.00000000e+000</D>
#         <M>0.0</M>
#         <CPcor>-9.57000000e-008</CPcor>
#       </Coefficients>
#       <Coefficients equation="1" >
#         <G>-9.80638400e-001</G>
#         <H>1.49497500e-001</H>
#         <I>-2.41942600e-004</I>
#         <J>4.16785600e-005</J>
#         <CPcor>-9.57000000e-008</CPcor>
#         <CTcor>3.2500e-006</CTcor>
#         <!-- WBOTC not applicable unless ConductivityType = 1. -->
#         <WBOTC>1.95004100e-007</WBOTC>
#       </Coefficients>
#       <Slope>1.00000000</Slope>
#       <Offset>0.00000</Offset>
#     </ConductivitySensor>
#   </sensor>
# </Sensors>
# datcnv_date = Jun 13 2024 14:46:29, 7.26.7.129 [datcnv_vars = 4]
# datcnv_in = C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_075m_9988.hex C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_075m_9988.xmlcon
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 4699
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\18082\Desktop\WHOTS-19_mcats\w19_085m_4699.asc
* Software Version 1.59
* Temperature SN = 4699
* Conductivity SN = 4699
* System UpLoad Time = Jun 10 2024 23:52:47
** whots-19
** 85m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 4699    06-10-2024  23:52:11
* not logging: received stop command
* sample interval = 240 seconds
* samplenumber = 130678, free = 59972
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 19.95 deg C


* S>
* SBE37-SM V 2.6b  4699
* temperature:  18-apr-23
*     TA0 = -1.013771e-04
*     TA1 = 3.010984e-04
*     TA2 = -4.108606e-06
*     TA3 = 2.013147e-07
* conductivity:  18-apr-23
*     G = -9.962566e-01
*     H = 1.536107e-01
*     I = -3.242679e-04
*     J = 5.198756e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -5.814154e-06
* pressure S/N 10209, range = 1450 psia:  14-apr-23
*     PA0 = 9.275078e-02
*     PA1 = 6.895788e-02
*     PA2 = -2.741533e-09
*     PTCA0 = -1.988741e+02
*     PTCA1 = -6.124735e-02
*     PTCA2 = 6.054749e-03
*     PTCSB0 = 2.500238e+01
*     PTCSB1 = -7.250000e-04
*     PTCSB2 = 0.000000e+00
*     POFFSET = 0.000000e+00
* rtc:  18-apr-23
*     RTCA0 = 9.999895e-01
*     RTCA1 = 1.587011e-06
*     RTCA2 = -2.869577e-08


* S>
*END*

# Metadata for Sensor Serial Number: 3791
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\danfi\Documents\Work\WHOTS-19_recovery\w19_095m_3791.asc
* Software Version 1.59
* Temperature SN = 3791
* Conductivity SN = 3791
* System UpLoad Time = Jun 07 2024 18:32:21
** whots-19
** 95m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 3791    08 Jun 2024  04:30:58
* not logging: received stop command
* sample interval = 180 seconds
* samplenumber = 171890, free = 61126
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* reference pressure = 95.0 db
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 22.34 deg C


* S>
* SBE37-SM V 2.6b  3791
* temperature:  13-apr-23
*     TA0 = 6.377279e-05
*     TA1 = 2.602906e-04
*     TA2 = -1.044213e-06
*     TA3 = 1.241293e-07
* conductivity:  13-apr-23
*     G = -1.017526e+00
*     H = 1.451710e-01
*     I = -4.207883e-05
*     J = 2.717897e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -1.284126e-05
* rtc:  13-apr-23
*     RTCA0 = 9.999860e-01
*     RTCA1 = 1.626248e-06
*     RTCA2 = -3.310045e-08


* S>
*END*

# Metadata for Sensor Serial Number: 2769
* Sea-Bird SBE37 Data File:
* FileName = C:\Users\danfi\Documents\Work\WHOTS-19_recovery\w19_105m_2769.asc
* Software Version 1.59
* Temperature SN = 2769
* Conductivity SN = 2769
* System UpLoad Time = Jun 07 2024 17:29:41
** whots-19
** 105m
* ds
* SBE37SM-RS232 v3.1  SERIAL NO. 2769  08 Jun 2024 03:29:05
* vMain =  6.99, vLith =  3.24
* samplenumber = 129653, free = 429587
* not logging, stop command
* sample interval = 240 seconds
* data format = converted engineering
* output salinity
* transmit real-time = no
* sync mode = no
* pump installed = no


* S>
* SBE37SM-RS232 V 3.1  2769
* temperature:  14-Apr-23
*     TA0 = -6.862328e-05
*     TA1 = 2.887448e-04
*     TA2 = -3.347584e-06
*     TA3 = 1.794880e-07
* conductivity:  14-Apr-23
*     G = -9.912924e-01
*     H = 1.515118e-01
*     I = -3.536343e-04
*     J = 5.242402e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -5.550443e-06
* pressure S/N 12364705, range = 1450 psia  30-Dec-22
*     PA0 = -2.778723e-01
*     PA1 = 4.402441e-03
*     PA2 = -2.574813e-11
*     PTCA0 = 5.248191e+05
*     PTCA1 = 0.000000e+00
*     PTCA2 = -0.000000e+00
*     PTCB0 = 0.000000e+00
*     PTCB1 = 0.000000e+00
*     PTCB2 = 0.000000e+00
*     PTEMPA0 = 0.000000e+00
*     PTEMPA1 = 0.000000e+00
*     PTEMPA2 = 0.000000e+00
*     POFFSET = 0.000000e+00


* S>
*END*

# Metadata for Sensor Serial Number: 25352
* Sea-Bird SBE37SM-RS232  Data File:
* FileName = C:\Users\danfi\Documents\Work\WHOTS-19_recovery\w19_120m_25352.hex
* Software version SeatermV2 2.8.0.119
* Temperature SN = 25352
* Conductivity SN = 25352
* System UpLoad Time = Jun 07 2024 16:00:07
* sample interval = 240 seconds
* <ApplicationData>
* <Seaterm232>
* <SoftwareVersion>2.8.0.119</SoftwareVersion>
* <BuildDate>07-Nov-2018</BuildDate>
* </Seaterm232>
* </ApplicationData>
* <InstrumentState>
* <HardwareData DeviceType='SBE37SM-RS232' SerialNumber='03725352'>
*
*    <Manufacturer>Sea-Bird Scientific</Manufacturer>
*
*    <FirmwareVersion>6.3.2</FirmwareVersion>
*
*    <FirmwareDate>Oct 23 2020 11:20:38</FirmwareDate>
*
*    <CommandSetVersion>1.3</CommandSetVersion>
*
*    <PCBAssembly SerialNum='274791' AssemblyNum='41661E'/>
*
*    <PCBAssembly SerialNum='274796' AssemblyNum='41783S'/>
*
*    <PCBAssembly SerialNum='274793' AssemblyNum='41785C'/>
*
*    <MfgDate>20Dec2022</MfgDate>
*
*    <FirmwareLoader>SBE 37-232-V3 FirmwareLoader V 1.0</FirmwareLoader>
*
*    <InternalSensors>
*
*       <Sensor id='Temperature'>
*
*          <type>temperature-1</type>
*
*          <SerialNumber>03725352</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Conductivity'>
*
*          <type>conductivity-1</type>
*
*          <SerialNumber>03725352</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Pressure'>
*
*          <type>strain-0</type>
*
*          <SerialNumber>5983494</SerialNumber>
*
*       </Sensor>
*
*    </InternalSensors>
*
* </HardwareData>
* <StatusData DeviceType='SBE37SM-RS232' SerialNumber='03725352'>
*
*    <DateTime>2024-06-08T00:29:15</DateTime>
*
*    <EventSummary numEvents='4'/>
*
*    <Power>
*
*       <vMain>13.27</vMain>
*
*       <vLith> 3.20</vLith>
*
*    </Power>
*
*    <MemorySummary>
*
*       <Bytes>1944105</Bytes>
*
*       <Samples>129607</Samples>
*
*       <SamplesFree>429633</SamplesFree>
*
*       <SampleLength>15</SampleLength>
*
*    </MemorySummary>
*
*    <AutonomousSampling>no, stop command</AutonomousSampling>
*
* </StatusData>
* <ConfigurationData DeviceType='SBE37SM-RS232' SerialNumber='03725352'>
*
*    <PressureInstalled>yes</PressureInstalled>
*
*    <SampleDataFormat>converted engineering</SampleDataFormat>
*
*    <TemperatureUnits>Celsius</TemperatureUnits>
*
*    <ConductivityUnits>S/m</ConductivityUnits>
*
*    <PressureUnits>Decibar</PressureUnits>
*
*    <OutputTemperature>yes</OutputTemperature>
*
*    <OutputConductivity>yes</OutputConductivity>
*
*    <OutputPressure>yes</OutputPressure>
*
*    <OutputSalinity>yes</OutputSalinity>
*
*    <OutputSV>no</OutputSV>
*
*    <OutputSC>no</OutputSC>
*
*    <SCCoeff>0.0200</SCCoeff>
*
*    <TxSampleNumber>no</TxSampleNumber>
*
*    <SampleInterval>240</SampleInterval>
*
*    <TxRealTime>no</TxRealTime>
*
*    <SyncMode>no</SyncMode>
*
*    <LegacyMode>no</LegacyMode>
*
*    <CompatibleMode>yes</CompatibleMode>
*
* </ConfigurationData>
* <CalibrationCoefficients DeviceType='SBE37SM-RS232' SerialNumber='03725352'>
*
*    <Calibration format='TEMP1' id='Temperature'>
*
*       <SerialNum>03725352</SerialNum>
*
*       <CalDate>29-Dec-22</CalDate>
*
*       <A0>-1.634622e-04</A0>
*
*       <A1>3.080939e-04</A1>
*
*       <A2>-4.074424e-06</A2>
*
*       <A3>1.910542e-07</A3>
*
*    </Calibration>
*
*    <Calibration format='WBCOND0' id='Conductivity'>
*
*       <SerialNum>03725352</SerialNum>
*
*       <CalDate>29-Dec-22</CalDate>
*
*       <G>-1.018884e+00</G>
*
*       <H>1.599526e-01</H>
*
*       <I>-3.755003e-04</I>
*
*       <J>5.563778e-05</J>
*
*       <PCOR>-9.570000e-08</PCOR>
*
*       <TCOR>3.250000e-06</TCOR>
*
*       <WBOTC>0.000000e+00</WBOTC>
*
*    </Calibration>
*
*    <Calibration format='STRAIN0' id='Pressure'>
*
*       <SerialNum>5983494</SerialNum>
*
*       <CalDate>21-Dec-22</CalDate>
*
*       <PA0>-6.195061e-01</PA0>
*
*       <PA1>3.187571e-02</PA1>
*
*       <PA2>2.481354e-09</PA2>
*
*       <PTCA0>5.237722e+05</PTCA0>
*
*       <PTCA1>-5.299658e+00</PTCA1>
*
*       <PTCA2>2.049859e-01</PTCA2>
*
*       <PTCB0>9.862354e+01</PTCB0>
*
*       <PTCB1>-2.586730e-03</PTCB1>
*
*       <PTCB2>0.000000e+00</PTCB2>
*
*       <PTEMPA0>-9.150144e+01</PTEMPA0>
*
*       <PTEMPA1>3.829939e-02</PTEMPA1>
*
*       <PTEMPA2>1.238160e-06</PTEMPA2>
*
*       <POFFSET>0.000000e+00</POFFSET>
*
*       <PRANGE>1.015300e+04</PRANGE>
*
*    </Calibration>
*
* </CalibrationCoefficients>
* <EventCounters DeviceType='SBE37SM-RS232' SerialNumber='03725352'>
*
*    <EventSummary numEvents='4'/>
*
*    <Event type='PON reset' count='4'/>
*
* </EventCounters></InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
** Cruise whots-19
** Depth 120m
* ]]>
* </UserHeaderInsert>
# nquan = 5
# nvalues = 129607
# units = specified
# name 0 = cond0S/m: Conductivity [S/m]
# name 1 = tv290C: Temperature [ITS-90, deg C]
# name 2 = prdM: Pressure, Strain Gauge [db]
# name 3 = timeJV2: Time, Instrument [julian days]
# name 4 = flag:  0.000e+00
# span 0 =  -0.000009,   5.349136
# span 1 =     0.5170,    26.3224
# span 2 =     -4.504,    123.285
# span 3 = 165.000000, 525.016667
# span 4 = 0.0000e+00, 0.0000e+00
# interval = seconds: 240
# start_time = Jun 14 2023 00:00:00 [Instrument's time stamp, first data scan]
# bad_flag = -9.990e-29
# <Sensors count="3" >
#   <sensor Channel="1" >
#     <!-- Count, Temperature -->
#     <TemperatureSensor SensorID="58" >
#       <SerialNumber>25352</SerialNumber>
#       <CalibrationDate>29-Dec-22</CalibrationDate>
#       <A0>-1.63462200e-004</A0>
#       <A1>3.08093900e-004</A1>
#       <A2>-4.07442400e-006</A2>
#       <A3>1.91054200e-007</A3>
#       <Slope>1.00000000</Slope>
#       <Offset>0.0000</Offset>
#     </TemperatureSensor>
#   </sensor>
#   <sensor Channel="2" >
#     <!-- Frequency 0, Conductivity -->
#     <ConductivitySensor SensorID="3" >
#       <SerialNumber>25352</SerialNumber>
#       <CalibrationDate>29-Dec-22</CalibrationDate>
#       <UseG_J>1</UseG_J>
#       <!-- Cell const and series R are applicable only for wide range sensors. -->
#       <SeriesR>0.0000</SeriesR>
#       <CellConst>2000.0000</CellConst>
#       <ConductivityType>1</ConductivityType>
#       <Coefficients equation="0" >
#         <A>0.00000000e+000</A>
#         <B>0.00000000e+000</B>
#         <C>0.00000000e+000</C>
#         <D>0.00000000e+000</D>
#         <M>0.0</M>
#         <CPcor>-9.57000000e-008</CPcor>
#       </Coefficients>
#       <Coefficients equation="1" >
#         <G>-1.01888400e+000</G>
#         <H>1.59952600e-001</H>
#         <I>-3.75500300e-004</I>
#         <J>5.56377800e-005</J>
#         <CPcor>-9.57000000e-008</CPcor>
#         <CTcor>3.2500e-006</CTcor>
#         <!-- WBOTC not applicable unless ConductivityType = 1. -->
#         <WBOTC>0.00000000e+000</WBOTC>
#       </Coefficients>
#       <Slope>1.00000000</Slope>
#       <Offset>0.00000</Offset>
#     </ConductivitySensor>
#   </sensor>
#   <sensor Channel="3" >
#     <!-- Count, Pressure, Strain Gauge -->
#     <PressureSensor SensorID="46" >
#       <SerialNumber>5983494</SerialNumber>
#       <CalibrationDate>21-Dec-22</CalibrationDate>
#       <PA0>-6.19506100e-001</PA0>
#       <PA1>3.18757100e-002</PA1>
#       <PA2>2.48135400e-009</PA2>
#       <PTEMPA0>-9.15014400e+001</PTEMPA0>
#       <PTEMPA1>3.82993900e-002</PTEMPA1>
#       <PTEMPA2>1.23816000e-006</PTEMPA2>
#       <PTCA0>5.23772200e+005</PTCA0>
#       <PTCA1>-5.29965800e+000</PTCA1>
#       <PTCA2>2.04985900e-001</PTCA2>
#       <PTCB0>9.86235400e+001</PTCB0>
#       <PTCB1>-2.58673000e-003</PTCB1>
#       <PTCB2>0.00000000e+000</PTCB2>
#       <Offset>0.000000</Offset>
#     </PressureSensor>
#   </sensor>
# </Sensors>
# datcnv_date = Jun 13 2024 14:47:27, 7.26.7.129 [datcnv_vars = 4]
# datcnv_in = C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_120m_25352.hex C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_120m_25352.xmlcon
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 25444
* Sea-Bird SBE37SM-RS232  Data File:
* FileName = C:\Users\danfi\Documents\Work\WHOTS-19_recovery\w19_135m_25444.hex
* Software version SeatermV2 2.8.0.119
* Temperature SN = 25444
* Conductivity SN = 25444
* System UpLoad Time = Jun 07 2024 14:15:20
* sample interval = 240 seconds
* <ApplicationData>
* <Seaterm232>
* <SoftwareVersion>2.8.0.119</SoftwareVersion>
* <BuildDate>07-Nov-2018</BuildDate>
* </Seaterm232>
* </ApplicationData>
* <InstrumentState>
* <HardwareData DeviceType='SBE37SM-RS232' SerialNumber='03725444'>
*
*    <Manufacturer>Sea-Bird Scientific</Manufacturer>
*
*    <FirmwareVersion>6.3.2</FirmwareVersion>
*
*    <FirmwareDate>Oct 23 2020 11:20:38</FirmwareDate>
*
*    <CommandSetVersion>1.3</CommandSetVersion>
*
*    <PCBAssembly SerialNum='274721' AssemblyNum='41661E'/>
*
*    <PCBAssembly SerialNum='274817' AssemblyNum='41783S'/>
*
*    <PCBAssembly SerialNum='274822' AssemblyNum='41785C'/>
*
*    <MfgDate>22Dec2022</MfgDate>
*
*    <FirmwareLoader>SBE 37-232-V3 FirmwareLoader V 1.0</FirmwareLoader>
*
*    <InternalSensors>
*
*       <Sensor id='Temperature'>
*
*          <type>temperature-1</type>
*
*          <SerialNumber>03725444</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Conductivity'>
*
*          <type>conductivity-1</type>
*
*          <SerialNumber>03725444</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Pressure'>
*
*          <type>strain-0</type>
*
*          <SerialNumber>12152941</SerialNumber>
*
*       </Sensor>
*
*    </InternalSensors>
*
* </HardwareData>
* <StatusData DeviceType='SBE37SM-RS232' SerialNumber='03725444'>
*
*    <DateTime>2024-06-07T22:44:09</DateTime>
*
*    <EventSummary numEvents='2'/>
*
*    <Power>
*
*       <vMain>13.39</vMain>
*
*       <vLith> 3.20</vLith>
*
*    </Power>
*
*    <MemorySummary>
*
*       <Bytes>1943715</Bytes>
*
*       <Samples>129581</Samples>
*
*       <SamplesFree>429659</SamplesFree>
*
*       <SampleLength>15</SampleLength>
*
*    </MemorySummary>
*
*    <AutonomousSampling>no, stop command</AutonomousSampling>
*
* </StatusData>
* <ConfigurationData DeviceType='SBE37SM-RS232' SerialNumber='03725444'>
*
*    <PressureInstalled>yes</PressureInstalled>
*
*    <SampleDataFormat>converted engineering</SampleDataFormat>
*
*    <TemperatureUnits>Celsius</TemperatureUnits>
*
*    <ConductivityUnits>S/m</ConductivityUnits>
*
*    <PressureUnits>Decibar</PressureUnits>
*
*    <OutputTemperature>yes</OutputTemperature>
*
*    <OutputConductivity>yes</OutputConductivity>
*
*    <OutputPressure>yes</OutputPressure>
*
*    <OutputSalinity>yes</OutputSalinity>
*
*    <OutputSV>no</OutputSV>
*
*    <OutputSC>no</OutputSC>
*
*    <SCCoeff>0.0200</SCCoeff>
*
*    <TxSampleNumber>no</TxSampleNumber>
*
*    <SampleInterval>240</SampleInterval>
*
*    <TxRealTime>no</TxRealTime>
*
*    <SyncMode>no</SyncMode>
*
*    <LegacyMode>no</LegacyMode>
*
*    <CompatibleMode>no</CompatibleMode>
*
* </ConfigurationData>
* <CalibrationCoefficients DeviceType='SBE37SM-RS232' SerialNumber='03725444'>
*
*    <Calibration format='TEMP1' id='Temperature'>
*
*       <SerialNum>03725444</SerialNum>
*
*       <CalDate>30-Dec-22</CalDate>
*
*       <A0>-1.463417e-04</A0>
*
*       <A1>3.120446e-04</A1>
*
*       <A2>-4.661027e-06</A2>
*
*       <A3>2.055070e-07</A3>
*
*    </Calibration>
*
*    <Calibration format='WBCOND0' id='Conductivity'>
*
*       <SerialNum>03725444</SerialNum>
*
*       <CalDate>30-Dec-22</CalDate>
*
*       <G>-1.004307e+00</G>
*
*       <H>1.542670e-01</H>
*
*       <I>-3.258636e-04</I>
*
*       <J>4.855151e-05</J>
*
*       <PCOR>-9.570000e-08</PCOR>
*
*       <TCOR>3.250000e-06</TCOR>
*
*       <WBOTC>2.282282e-07</WBOTC>
*
*    </Calibration>
*
*    <Calibration format='STRAIN0' id='Pressure'>
*
*       <SerialNum>12152941</SerialNum>
*
*       <CalDate>22-Dec-22</CalDate>
*
*       <PA0>1.338623e+00</PA0>
*
*       <PA1>3.179865e-02</PA1>
*
*       <PA2>-1.978555e-09</PA2>
*
*       <PTCA0>5.246397e+05</PTCA0>
*
*       <PTCA1>3.126805e+00</PTCA1>
*
*       <PTCA2>-1.035617e-01</PTCA2>
*
*       <PTCB0>2.521830e+01</PTCB0>
*
*       <PTCB1>-1.206030e-03</PTCB1>
*
*       <PTCB2>0.000000e+00</PTCB2>
*
*       <PTEMPA0>-7.118709e+01</PTEMPA0>
*
*       <PTEMPA1>5.232046e-02</PTEMPA1>
*
*       <PTEMPA2>-7.376980e-07</PTEMPA2>
*
*       <POFFSET>0.000000e+00</POFFSET>
*
*       <PRANGE>1.015300e+04</PRANGE>
*
*    </Calibration>
*
* </CalibrationCoefficients>
* <EventCounters DeviceType='SBE37SM-RS232' SerialNumber='03725444'>
*
*    <EventSummary numEvents='2'/>
*
*    <Event type='PON reset' count='2'/>
*
* </EventCounters></InstrumentState>
* <UserHeaderInsert>
* <![CDATA[
** Cruise whots-19
** Depth 135m
* ]]>
* </UserHeaderInsert>
# nquan = 5
# nvalues = 129581
# units = specified
# name 0 = cond0S/m: Conductivity [S/m]
# name 1 = tv290C: Temperature [ITS-90, deg C]
# name 2 = prdM: Pressure, Strain Gauge [db]
# name 3 = timeJV2: Time, Instrument [julian days]
# name 4 = flag:  0.000e+00
# span 0 =   0.000003,   5.342637
# span 1 =     0.5230,    31.8500
# span 2 =     -1.605,    138.236
# span 3 = 165.000000, 524.944444
# span 4 = 0.0000e+00, 0.0000e+00
# interval = seconds: 240
# start_time = Jun 14 2023 00:00:00 [Instrument's time stamp, first data scan]
# bad_flag = -9.990e-29
# <Sensors count="3" >
#   <sensor Channel="1" >
#     <!-- Count, Temperature -->
#     <TemperatureSensor SensorID="58" >
#       <SerialNumber>25444</SerialNumber>
#       <CalibrationDate>30-Dec-22</CalibrationDate>
#       <A0>-1.46341700e-004</A0>
#       <A1>3.12044600e-004</A1>
#       <A2>-4.66102700e-006</A2>
#       <A3>2.05507000e-007</A3>
#       <Slope>1.00000000</Slope>
#       <Offset>0.0000</Offset>
#     </TemperatureSensor>
#   </sensor>
#   <sensor Channel="2" >
#     <!-- Frequency 0, Conductivity -->
#     <ConductivitySensor SensorID="3" >
#       <SerialNumber>25444</SerialNumber>
#       <CalibrationDate>30-Dec-22</CalibrationDate>
#       <UseG_J>1</UseG_J>
#       <!-- Cell const and series R are applicable only for wide range sensors. -->
#       <SeriesR>0.0000</SeriesR>
#       <CellConst>2000.0000</CellConst>
#       <ConductivityType>1</ConductivityType>
#       <Coefficients equation="0" >
#         <A>0.00000000e+000</A>
#         <B>0.00000000e+000</B>
#         <C>0.00000000e+000</C>
#         <D>0.00000000e+000</D>
#         <M>0.0</M>
#         <CPcor>-9.57000000e-008</CPcor>
#       </Coefficients>
#       <Coefficients equation="1" >
#         <G>-1.00430700e+000</G>
#         <H>1.54267000e-001</H>
#         <I>-3.25863600e-004</I>
#         <J>4.85515100e-005</J>
#         <CPcor>-9.57000000e-008</CPcor>
#         <CTcor>3.2500e-006</CTcor>
#         <!-- WBOTC not applicable unless ConductivityType = 1. -->
#         <WBOTC>2.28228200e-007</WBOTC>
#       </Coefficients>
#       <Slope>1.00000000</Slope>
#       <Offset>0.00000</Offset>
#     </ConductivitySensor>
#   </sensor>
#   <sensor Channel="3" >
#     <!-- Count, Pressure, Strain Gauge -->
#     <PressureSensor SensorID="46" >
#       <SerialNumber>52941</SerialNumber>
#       <CalibrationDate>22-Dec-22</CalibrationDate>
#       <PA0>1.33862300e+000</PA0>
#       <PA1>3.17986500e-002</PA1>
#       <PA2>-1.97855500e-009</PA2>
#       <PTEMPA0>-7.11870900e+001</PTEMPA0>
#       <PTEMPA1>5.23204600e-002</PTEMPA1>
#       <PTEMPA2>-7.37698000e-007</PTEMPA2>
#       <PTCA0>5.24639700e+005</PTCA0>
#       <PTCA1>3.12680500e+000</PTCA1>
#       <PTCA2>-1.03561700e-001</PTCA2>
#       <PTCB0>2.52183000e+001</PTCB0>
#       <PTCB1>-1.20603000e-003</PTCB1>
#       <PTCB2>0.00000000e+000</PTCB2>
#       <Offset>0.000000</Offset>
#     </PressureSensor>
#   </sensor>
# </Sensors>
# datcnv_date = Jun 13 2024 14:47:46, 7.26.7.129 [datcnv_vars = 4]
# datcnv_in = C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_135m_25444.hex C:\Users\santi\Documents\Work\whots\whots19_mooring\wh19_microcat_data\WHOTS-19_microcat_data\WHOTS-19_microcat_data\w19_135m_25444.xmlcon
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 4701
* Sea-Bird SBE37 Data File:
* FileName = C:\Documents and Settings\Administrator\Desktop\WHOTS-19_recovery\w19_155m_4701_2ndtry.asc
* Software Version 1.58
* Temperature SN = 4701
* Conductivity SN = 4701
* System UpLoad Time = Jun 08 2024 03:43:54
** whots-19
** 155m
* ds
* SBE37-SM V 2.6b  SERIAL NO. 4701    08 Jun 2024  03:42:44
* not logging: received stop command
* sample interval = 240 seconds
* samplenumber = 129571, free = 61079
* do not transmit real-time data
* output salinity with each sample
* do not output sound velocity with each sample
* store time with each sample
* number of samples to average = 4
* serial sync mode disabled
* wait time after serial sync sampling = 30 seconds
* internal pump not installed
* temperature = 23.28 deg C


* S>
* SBE37-SM V 2.6b  4701
* temperature:  18-apr-23
*     TA0 = 2.105019e-05
*     TA1 = 2.749298e-04
*     TA2 = -2.105408e-06
*     TA3 = 1.517139e-07
* conductivity:  18-apr-23
*     G = -1.006527e+00
*     H = 1.486128e-01
*     I = -2.362030e-05
*     J = 2.769558e-05
*     CPCOR = -9.570000e-08
*     CTCOR = 3.250000e-06
*     WBOTC = -9.383437e-06
* pressure S/N 10211, range = 1450 psia:  14-apr-23
*     PA0 = -5.075048e-02
*     PA1 = 6.946433e-02
*     PA2 = -1.651236e-08
*     PTCA0 = -1.961793e+02
*     PTCA1 = -3.413052e-01
*     PTCA2 = 1.479438e-02
*     PTCSB0 = 2.496538e+01
*     PTCSB1 = -1.925000e-03
*     PTCSB2 = 0.000000e+00
*     POFFSET = -6.300000e-02
* rtc:  18-apr-23
*     RTCA0 = 9.999870e-01
*     RTCA1 = 1.789222e-06
*     RTCA2 = -3.228207e-08


* S>
*END*

# Metadata for Sensor Serial Number: 11381
* Sea-Bird SBE37SM-RS232  Data File:
* FileName = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE37\SBE37_11381.hex
* Software version SeatermV2 2.8.0.119
* Temperature SN = 11381
* Conductivity SN = 11381
* System UpLoad Time = Jun 08 2024 00:14:52
* sample interval = 300 seconds
* <ApplicationData>
* <Seaterm232>
* <SoftwareVersion>2.8.0.119</SoftwareVersion>
* <BuildDate>07-Nov-2018</BuildDate>
* </Seaterm232>
* </ApplicationData>
* <InstrumentState>
* <HardwareData DeviceType='SBE37SM-RS232' SerialNumber='03711381'>
*
*    <Manufacturer>Sea-Bird Electronics, Inc.</Manufacturer>
*
*    <FirmwareVersion>3.1</FirmwareVersion>
*
*    <FirmwareDate>Jan 20 2012 17:33:01</FirmwareDate>
*
*    <PCBAssembly>41647.1</PCBAssembly>
*
*    <PCBAssembly>41610B</PCBAssembly>
*
*    <PCBAssembly>41611D</PCBAssembly>
*
*    <MfgDate>19-Oct-2013</MfgDate>
*
*    <FirmwareLoader>SBE 37 FirmwareLoader V 1.0</FirmwareLoader>
*
*    <InternalSensors>
*
*       <Sensor id='Temperature'>
*
*          <type>temperature-1</type>
*
*          <SerialNumber>03711381</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Conductivity'>
*
*          <type>conductivity-1</type>
*
*          <SerialNumber>03711381</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Pressure'>
*
*          <type>strain-0</type>
*
*          <SerialNumber>2146836</SerialNumber>
*
*       </Sensor>
*
*    </InternalSensors>
*
* </HardwareData>
* <StatusData DeviceType='SBE37SM-RS232' SerialNumber='03711381'>
*
*    <DateTime>2024-06-07T23:02:10</DateTime>
*
*    <EventSummary numEvents='1'/>
*
*    <Power>
*
*       <vMain> 6.92</vMain>
*
*       <vLith> 3.23</vLith>
*
*    </Power>
*
*    <MemorySummary>
*
*       <Bytes>1546395</Bytes>
*
*       <Samples>103093</Samples>
*
*       <SamplesFree>456147</SamplesFree>
*
*       <SampleLength>15</SampleLength>
*
*    </MemorySummary>
*
*    <AutonomousSampling>no, stop command</AutonomousSampling>
*
* </StatusData>
* <ConfigurationData DeviceType='SBE37SM-RS232' SerialNumber='03711381'>
*
*    <PressureInstalled>yes</PressureInstalled>
*
*    <PumpInstalled>no</PumpInstalled>
*
*    <SampleDataFormat>converted engineering</SampleDataFormat>
*
*    <OutputSalinity>no</OutputSalinity>
*
*    <OutputSV>no</OutputSV>
*
*    <TxRealTime>no</TxRealTime>
*
*    <SampleInterval>300</SampleInterval>
*
*    <SyncMode>no</SyncMode>
*
* </ConfigurationData>
* <CalibrationCoefficients DeviceType='SBE37SM-RS232' SerialNumber='03711381'>
*
*    <Calibration format='TEMP1' id='Temperature'>
*
*       <SerialNum>03711381</SerialNum>
*
*       <CalDate>10-Feb-23</CalDate>
*
*       <A0>-7.840626e-05</A0>
*
*       <A1>3.019964e-04</A1>
*
*       <A2>-4.194832e-06</A2>
*
*       <A3>1.960253e-07</A3>
*
*    </Calibration>
*
*    <Calibration format='WBCOND0' id='Conductivity'>
*
*       <SerialNum>03711381</SerialNum>
*
*       <CalDate>10-Feb-23</CalDate>
*
*       <G>-9.817091e-01</G>
*
*       <H>1.392003e-01</H>
*
*       <I>-1.946812e-04</I>
*
*       <J>3.414003e-05</J>
*
*       <PCOR>-9.570000e-08</PCOR>
*
*       <TCOR>3.250000e-06</TCOR>
*
*       <WBOTC>7.523668e-07</WBOTC>
*
*    </Calibration>
*
*    <Calibration format='STRAIN0' id='Pressure'>
*
*       <SerialNum>2146836</SerialNum>
*
*       <CalDate>07-Feb-23</CalDate>
*
*       <PA0>-1.437911e+01</PA0>
*
*       <PA1>3.134084e-02</PA1>
*
*       <PA2>9.389038e-10</PA2>
*
*       <PTCA0>5.300600e+05</PTCA0>
*
*       <PTCA1>-2.440445e+01</PTCA1>
*
*       <PTCA2>1.723165e-01</PTCA2>
*
*       <PTCB0>1.037944e+02</PTCB0>
*
*       <PTCB1>-7.587441e-03</PTCB1>
*
*       <PTCB2>0.000000e+00</PTCB2>
*
*       <PTEMPA0>-9.626943e+01</PTEMPA0>
*
*       <PTEMPA1>3.959023e-02</PTEMPA1>
*
*       <PTEMPA2>1.402931e-06</PTEMPA2>
*
*       <POFFSET>0.000000e+00</POFFSET>
*
*       <PRANGE>1.015300e+04</PRANGE>
*
*    </Calibration>
*
* </CalibrationCoefficients>
* <EventCounters DeviceType='SBE37SM-RS232' SerialNumber='03711381'>
*
*    <EventSummary numEvents='1'/>
*
*    <Event type='PON reset' count='1'/>
*
* </EventCounters></InstrumentState>
# nquan = 6
# nvalues = 103093
# units = specified
# name 0 = cond0S/m: Conductivity [S/m]
# name 1 = tv290C: Temperature [ITS-90, deg C]
# name 2 = sal00: Salinity, Practical [PSU]
# name 3 = prdM: Pressure, Strain Gauge [db]
# name 4 = timeJ: Julian Days
# name 5 = flag:  0.000e+00
# span 0 =   0.000009,   5.360072
# span 1 =     1.4718,    32.1715
# span 2 =     0.0018,    35.2484
# span 3 =     -3.150,   4726.497
# span 4 = 167.000012, 524.958345
# span 5 = 0.0000e+00, 0.0000e+00
# interval = seconds: 300
# start_time = Jun 16 2023 00:00:01 [Instrument's time stamp, first data scan]
# bad_flag = -9.990e-29
# <Sensors count="3" >
#   <sensor Channel="1" >
#     <!-- Count, Temperature -->
#     <TemperatureSensor SensorID="58" >
#       <SerialNumber>11381</SerialNumber>
#       <CalibrationDate>10-Feb-23</CalibrationDate>
#       <A0>-7.84062600e-005</A0>
#       <A1>3.01996400e-004</A1>
#       <A2>-4.19483200e-006</A2>
#       <A3>1.96025300e-007</A3>
#       <Slope>1.00000000</Slope>
#       <Offset>0.0000</Offset>
#     </TemperatureSensor>
#   </sensor>
#   <sensor Channel="2" >
#     <!-- Frequency 0, Conductivity -->
#     <ConductivitySensor SensorID="3" >
#       <SerialNumber>11381</SerialNumber>
#       <CalibrationDate>10-Feb-23</CalibrationDate>
#       <UseG_J>1</UseG_J>
#       <!-- Cell const and series R are applicable only for wide range sensors. -->
#       <SeriesR>0.0000</SeriesR>
#       <CellConst>2000.0000</CellConst>
#       <ConductivityType>1</ConductivityType>
#       <Coefficients equation="0" >
#         <A>0.00000000e+000</A>
#         <B>0.00000000e+000</B>
#         <C>0.00000000e+000</C>
#         <D>0.00000000e+000</D>
#         <M>0.0</M>
#         <CPcor>-9.57000000e-008</CPcor>
#       </Coefficients>
#       <Coefficients equation="1" >
#         <G>-9.81709100e-001</G>
#         <H>1.39200300e-001</H>
#         <I>-1.94681200e-004</I>
#         <J>3.41400300e-005</J>
#         <CPcor>-9.57000000e-008</CPcor>
#         <CTcor>3.2500e-006</CTcor>
#         <!-- WBOTC not applicable unless ConductivityType = 1. -->
#         <WBOTC>7.52366800e-007</WBOTC>
#       </Coefficients>
#       <Slope>1.00000000</Slope>
#       <Offset>0.00000</Offset>
#     </ConductivitySensor>
#   </sensor>
#   <sensor Channel="3" >
#     <!-- Count, Pressure, Strain Gauge -->
#     <PressureSensor SensorID="46" >
#       <SerialNumber>2146836</SerialNumber>
#       <CalibrationDate>07-Feb-23</CalibrationDate>
#       <PA0>-1.43791100e+001</PA0>
#       <PA1>3.13408400e-002</PA1>
#       <PA2>9.38903800e-010</PA2>
#       <PTEMPA0>-9.62694300e+001</PTEMPA0>
#       <PTEMPA1>3.95902300e-002</PTEMPA1>
#       <PTEMPA2>1.40293100e-006</PTEMPA2>
#       <PTCA0>5.30060000e+005</PTCA0>
#       <PTCA1>-2.44044500e+001</PTCA1>
#       <PTCA2>1.72316500e-001</PTCA2>
#       <PTCB0>1.03794400e+002</PTCB0>
#       <PTCB1>-7.58744100e-003</PTCB1>
#       <PTCB2>0.00000000e+000</PTCB2>
#       <Offset>0.000000</Offset>
#     </PressureSensor>
#   </sensor>
# </Sensors>
# datcnv_date = Jun 08 2024 00:27:19, 7.26.7.129 [datcnv_vars = 5]
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE37\sbe37_11381.hex C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE37\SBE37_11381.xmlcon
# datcnv_skipover = 0
# file_type = ascii
*END*

# Metadata for Sensor Serial Number: 11380
* Sea-Bird SBE37SM-RS232  Data File:
* FileName = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE37\SBE37_11380.hex
* Software version SeatermV2 2.8.0.119
* Temperature SN = 11380
* Conductivity SN = 11380
* System UpLoad Time = Jun 08 2024 00:17:33
* sample interval = 300 seconds
* <ApplicationData>
* <Seaterm232>
* <SoftwareVersion>2.8.0.119</SoftwareVersion>
* <BuildDate>07-Nov-2018</BuildDate>
* </Seaterm232>
* </ApplicationData>
* <InstrumentState>
* <HardwareData DeviceType='SBE37SM-RS232' SerialNumber='03711380'>
*
*    <Manufacturer>Sea-Bird Electronics, Inc.</Manufacturer>
*
*    <FirmwareVersion>3.1</FirmwareVersion>
*
*    <FirmwareDate>Jan 20 2012 17:33:01</FirmwareDate>
*
*    <PCBAssembly>41647.1</PCBAssembly>
*
*    <PCBAssembly>41610B</PCBAssembly>
*
*    <PCBAssembly>41611D</PCBAssembly>
*
*    <MfgDate>13-Nov-2013</MfgDate>
*
*    <FirmwareLoader>SBE 37 FirmwareLoader V 1.0</FirmwareLoader>
*
*    <InternalSensors>
*
*       <Sensor id='Temperature'>
*
*          <type>temperature-1</type>
*
*          <SerialNumber>03711380</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Conductivity'>
*
*          <type>conductivity-1</type>
*
*          <SerialNumber>03711380</SerialNumber>
*
*       </Sensor>
*
*       <Sensor id='Pressure'>
*
*          <type>strain-0</type>
*
*          <SerialNumber>2146835</SerialNumber>
*
*       </Sensor>
*
*    </InternalSensors>
*
* </HardwareData>
* <StatusData DeviceType='SBE37SM-RS232' SerialNumber='03711380'>
*
*    <DateTime>2024-06-07T23:04:54</DateTime>
*
*    <EventSummary numEvents='4'/>
*
*    <Power>
*
*       <vMain> 6.99</vMain>
*
*       <vLith> 2.99</vLith>
*
*    </Power>
*
*    <MemorySummary>
*
*       <Bytes>1546395</Bytes>
*
*       <Samples>103093</Samples>
*
*       <SamplesFree>456147</SamplesFree>
*
*       <SampleLength>15</SampleLength>
*
*    </MemorySummary>
*
*    <AutonomousSampling>no, stop command</AutonomousSampling>
*
* </StatusData>
* <ConfigurationData DeviceType='SBE37SM-RS232' SerialNumber='03711380'>
*
*    <PressureInstalled>yes</PressureInstalled>
*
*    <PumpInstalled>no</PumpInstalled>
*
*    <SampleDataFormat>converted engineering</SampleDataFormat>
*
*    <OutputSalinity>no</OutputSalinity>
*
*    <OutputSV>no</OutputSV>
*
*    <TxRealTime>no</TxRealTime>
*
*    <SampleInterval>300</SampleInterval>
*
*    <SyncMode>no</SyncMode>
*
* </ConfigurationData>
* <CalibrationCoefficients DeviceType='SBE37SM-RS232' SerialNumber='03711380'>
*
*    <Calibration format='TEMP1' id='Temperature'>
*
*       <SerialNum>03711380</SerialNum>
*
*       <CalDate>15-Feb-23</CalDate>
*
*       <A0>-1.086200e-04</A0>
*
*       <A1>3.084300e-04</A1>
*
*       <A2>-4.591820e-06</A2>
*
*       <A3>2.050536e-07</A3>
*
*    </Calibration>
*
*    <Calibration format='WBCOND0' id='Conductivity'>
*
*       <SerialNum>03711380</SerialNum>
*
*       <CalDate>15-Feb-23</CalDate>
*
*       <G>-9.942626e-01</G>
*
*       <H>1.398204e-01</H>
*
*       <I>-1.799830e-04</I>
*
*       <J>3.349853e-05</J>
*
*       <PCOR>-9.570000e-08</PCOR>
*
*       <TCOR>3.250000e-06</TCOR>
*
*       <WBOTC>2.809963e-07</WBOTC>
*
*    </Calibration>
*
*    <Calibration format='STRAIN0' id='Pressure'>
*
*       <SerialNum>2146835</SerialNum>
*
*       <CalDate>09-Feb-23</CalDate>
*
*       <PA0>-8.778848e+00</PA0>
*
*       <PA1>3.111777e-02</PA1>
*
*       <PA2>2.103285e-09</PA2>
*
*       <PTCA0>5.288735e+05</PTCA0>
*
*       <PTCA1>-1.731807e+01</PTCA1>
*
*       <PTCA2>2.151018e-01</PTCA2>
*
*       <PTCB0>1.011848e+02</PTCB0>
*
*       <PTCB1>-2.443741e-03</PTCB1>
*
*       <PTCB2>0.000000e+00</PTCB2>
*
*       <PTEMPA0>-9.571512e+01</PTEMPA0>
*
*       <PTEMPA1>4.049506e-02</PTEMPA1>
*
*       <PTEMPA2>1.149109e-06</PTEMPA2>
*
*       <POFFSET>0.000000e+00</POFFSET>
*
*       <PRANGE>1.015300e+04</PRANGE>
*
*    </Calibration>
*
* </CalibrationCoefficients>
* <EventCounters DeviceType='SBE37SM-RS232' SerialNumber='03711380'>
*
*    <EventSummary numEvents='4'/>
*
*    <Event type='PON reset' count='3'/>
*
*    <Event type='alarm long' count='1'/>
*
* </EventCounters></InstrumentState>
# nquan = 6
# nvalues = 103093
# units = specified
# name 0 = cond0S/m: Conductivity [S/m]
# name 1 = tv290C: Temperature [ITS-90, deg C]
# name 2 = sal00: Salinity, Practical [PSU]
# name 3 = prdM: Pressure, Strain Gauge [db]
# name 4 = timeJ: Julian Days
# name 5 = flag:  0.000e+00
# span 0 =  -0.000098,   5.359559
# span 1 =     1.4716,    33.0106
# span 2 =     0.0000,    35.2128
# span 3 =     -1.888,   4739.908
# span 4 = 167.000012, 524.958345
# span 5 = 0.0000e+00, 0.0000e+00
# interval = seconds: 300
# start_time = Jun 16 2023 00:00:01 [Instrument's time stamp, first data scan]
# bad_flag = -9.990e-29
# <Sensors count="3" >
#   <sensor Channel="1" >
#     <!-- Count, Temperature -->
#     <TemperatureSensor SensorID="58" >
#       <SerialNumber>11380</SerialNumber>
#       <CalibrationDate>15-Feb-23</CalibrationDate>
#       <A0>-1.08620000e-004</A0>
#       <A1>3.08430000e-004</A1>
#       <A2>-4.59182000e-006</A2>
#       <A3>2.05053600e-007</A3>
#       <Slope>1.00000000</Slope>
#       <Offset>0.0000</Offset>
#     </TemperatureSensor>
#   </sensor>
#   <sensor Channel="2" >
#     <!-- Frequency 0, Conductivity -->
#     <ConductivitySensor SensorID="3" >
#       <SerialNumber>11380</SerialNumber>
#       <CalibrationDate>15-Feb-23</CalibrationDate>
#       <UseG_J>1</UseG_J>
#       <!-- Cell const and series R are applicable only for wide range sensors. -->
#       <SeriesR>0.0000</SeriesR>
#       <CellConst>2000.0000</CellConst>
#       <ConductivityType>1</ConductivityType>
#       <Coefficients equation="0" >
#         <A>0.00000000e+000</A>
#         <B>0.00000000e+000</B>
#         <C>0.00000000e+000</C>
#         <D>0.00000000e+000</D>
#         <M>0.0</M>
#         <CPcor>-9.57000000e-008</CPcor>
#       </Coefficients>
#       <Coefficients equation="1" >
#         <G>-9.94262600e-001</G>
#         <H>1.39820400e-001</H>
#         <I>-1.79983000e-004</I>
#         <J>3.34985300e-005</J>
#         <CPcor>-9.57000000e-008</CPcor>
#         <CTcor>3.2500e-006</CTcor>
#         <!-- WBOTC not applicable unless ConductivityType = 1. -->
#         <WBOTC>2.80996300e-007</WBOTC>
#       </Coefficients>
#       <Slope>1.00000000</Slope>
#       <Offset>0.00000</Offset>
#     </ConductivitySensor>
#   </sensor>
#   <sensor Channel="3" >
#     <!-- Count, Pressure, Strain Gauge -->
#     <PressureSensor SensorID="46" >
#       <SerialNumber>2146835</SerialNumber>
#       <CalibrationDate>09-Feb-23</CalibrationDate>
#       <PA0>-8.77884800e+000</PA0>
#       <PA1>3.11177700e-002</PA1>
#       <PA2>2.10328500e-009</PA2>
#       <PTEMPA0>-9.57151200e+001</PTEMPA0>
#       <PTEMPA1>4.04950600e-002</PTEMPA1>
#       <PTEMPA2>1.14910900e-006</PTEMPA2>
#       <PTCA0>5.28873500e+005</PTCA0>
#       <PTCA1>-1.73180700e+001</PTCA1>
#       <PTCA2>2.15101800e-001</PTCA2>
#       <PTCB0>1.01184800e+002</PTCB0>
#       <PTCB1>-2.44374100e-003</PTCB1>
#       <PTCB2>0.00000000e+000</PTCB2>
#       <Offset>0.000000</Offset>
#     </PressureSensor>
#   </sensor>
# </Sensors>
# datcnv_date = Jun 08 2024 00:27:06, 7.26.7.129 [datcnv_vars = 5]
# datcnv_in = C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE37\sbe37_11380.hex C:\Users\Rtgra\Documents\Buoy Systems\ORS\WHOTS\W19\DATA\SBE37\SBE37_11380.xmlcon
# datcnv_skipover = 0
# file_type = ascii
*END*